Home Login Contact Us Cart Logout
Watlow Style 72 Pipe Clamp Thermocouple
Plastics Standard - Thousands Available in Days
Watlow Style 72 Pipe Clamp Thermocouple temperature sensors have a stainless steel clamp that allows temperature measurement without drilling or tapping. Ideal for measuring pipe temperatures. They come in 7 different clamp band diameter ranges.

Achieving specified temperature levels is critical to industrial processes. It's imperative that temperature sensors are designed and manufactured to exacting specifications for accuracy and reliability. Watlow is committed to providing you with the most accurate, high-integrity temperature measurement products possible. Watlow offers from stock the greatest breadth of contact temperature measurement sensors and related components. Whatever your temperature sensing needs, Watlow can provide the optimum configuration, with the accuracy you require.

FAST DELIVERY--Watlow’s “custom-tailored” stock program allows quick shipment on over 5,000,000 thermocouple variations. The program includes: 32 standard sheath lengths; lead lengths from 6 to 999 inches; stainless steel braid or hose protection; J, K, T, & E calibrations; grounded, ungrounded & exposed junctions; flat, rounded and drill point tips.

TERMINATION OPTIONS include: 2-1/2” split leads, spade lugs, 1/2” BX connector & space lugs, 1/4” & 3/16” push on female disconnect, standard size male & female TC plugs, miniature size male & female TC plugs. See chart below.

To order a Watlow Pipe Clamp Thermocouple build the desired 11-digit model part number using the ordering information form below.

Download Watlow Style 72 Thermocouple Catalog Page (pdf)
Custom Ordering Information -
Watlow Pipe Clamp Style Thermocouples
7 2 X ____ ____ G ____ ____ ____ ____ ____
1 2 3 4 5 6 7 8 9 10 11
To order, make a selection in each category below, enter the quantity needed,
then click the "submit" button at the bottom of the page.
The part number and price will be displayed on the next page.
NOTE: There is now a 5-piece Minimum Order Quantity for this item.
1-2 Construction Style
72 = Pipe clamp thermocouple

3. Sheath Diameter
X = Not applicable

4. Calibration (choose J ,K, T or E)
J = Type J
K = Type K
T = Type T
E = Type E

5. Lead Protection (choose S, B, U or W)
S = Fiberglass with stainless steel overbraid (24 gauge stranded)
B = Fiberglass with stainless steel overbraid (20 gauge stranded)
U = PFA with stainless steel overbraid (24 gauge stranded)
W = PFA with stainless steel overbraid (20 gauge stranded)

6. Junction
G = Grounded

7. Clamp Band Diameter Range (inches) (choose A, B, C, D, E, F or G)
A = 11/16 to 1-1/4
B = 1-1/4 to 2-1/4
C = 2-1/4 to 3-1/4
D = 3-1/4 to 4-1/4
E = 4-1/4 to 5
F = 5 to 6
G = 6 to 7

8-10. Lead Length (whole inches) (enter 6 to 360)
Inches

11. Termination (choose A, B, C, D, E, F, G or H)
A = Standard, 2-1/2 inch split leads
B = 2-1/2 inch split leads with #6 spade lugs
C = 2-1/2 inch split leads with #6 spade lugs and BX connector
D = Standard male plug, quick disconnect
E = Standard female jack, quick disconnect
F = Miniature male plug, quick disc. (24 gauge wire only, no hose)
G = Miniature female jack, quick disc. (24 gauge wire only, no hose)
H = 1/4 inch push-on connector

ENTER QUANTITY NEEDED (5-Piece Minimum Order Quantity)


Watlow Thermocouple Termination Options
A = 2-1/2" Split Leads B = Spade Lugs D = Standard Plug-Male E = Standard Plug-Female
C = BX Connector with
Space Lugs
H = 1/4" Push On
Female Quick Disconnect
F = Miniature Plug-Male G = Miniature Plug-Female

This page last modified on 1/16/2023

Untitled Page
About WCPE/Contact Info | Terms & Conditions | Business Hours M-F 8-4PST
For Packaging Equipment & Bag Sealers see our WCPSealers.com website!